TY - JOUR
T1 - A new device for assessing ankle dorsiflexion motion
T2 - Reliability and Validity
AU - Wilken, Jason
AU - Smita, Rao
AU - Estin, Miriam
AU - Saltzman, Charles
AU - John Yack, H.
PY - 2011/4
Y1 - 2011/4
N2 - STUDY DESIGN: Clinical measurement. OBJECTIVE: To determine the validity and reliability of measures obtained using a custom-made device for assessing ankle dorsiflexion motion and stiffness. BACKGROUND: Limited dorsiflexion has been implicated in the evolution of foot pain in a number of clinical populations. Assessment of ankle dorsiflexion range of motion (ROM) is, therefore, commonly performed as part of a foot and ankle examination. Conventional goniometric assessment methods have demonstrated limited intertester reliability, while alternative methods of measurements are generally more difficult to use. The Iowa ankle range of motion (IAROM) device was designed in an attempt to develop a simple, clinically relevant, and time- and cost-effective tool to measure ankle dorsiflexion range of motion and stiffness. METHODS: Validity and intertester reliability of dorsiflexion range-of-motion measures using the IAROM device were assessed at 10, 15, 20, and 25 Nm of passively applied dorsiflexion torque, with both the knee extended and flexed approximately 20°. Stiffness (change in torque/change in dorsiflexion angle) values were determined using the angular change obtained between the 15- and 25-Nm torque levels. Convergent validity (n = 12) was assessed through comparison of ankle dorsiflexion angles measured simultaneously with the IAROM device and an optoelectronic motion analysis system. Intertester reliability (n = 17) was assessed by 2 testers who took measurements within the same day. RESULTS: Validity testing demonstrated excellent agreement (intraclass correlation coefficient [ICC] values ranging from 0.95 to 0.98). Reliability testing demonstrated good to excellent intertester agreement (ICC values ranging from 0.90 to 0.95). The ICCs for ankle joint dorsiflexion stiffness were .71 and .85 for the knee in an extended and flexed position, respectively. CONCLUSION: The IAROM device provides valid and reliable measurement of ankle dorsiflexion ROM. The IAROM device also allows calculation of stiffness by measuring ROM at multiple torque levels, although the reliability of the measurement is not optimal.
AB - STUDY DESIGN: Clinical measurement. OBJECTIVE: To determine the validity and reliability of measures obtained using a custom-made device for assessing ankle dorsiflexion motion and stiffness. BACKGROUND: Limited dorsiflexion has been implicated in the evolution of foot pain in a number of clinical populations. Assessment of ankle dorsiflexion range of motion (ROM) is, therefore, commonly performed as part of a foot and ankle examination. Conventional goniometric assessment methods have demonstrated limited intertester reliability, while alternative methods of measurements are generally more difficult to use. The Iowa ankle range of motion (IAROM) device was designed in an attempt to develop a simple, clinically relevant, and time- and cost-effective tool to measure ankle dorsiflexion range of motion and stiffness. METHODS: Validity and intertester reliability of dorsiflexion range-of-motion measures using the IAROM device were assessed at 10, 15, 20, and 25 Nm of passively applied dorsiflexion torque, with both the knee extended and flexed approximately 20°. Stiffness (change in torque/change in dorsiflexion angle) values were determined using the angular change obtained between the 15- and 25-Nm torque levels. Convergent validity (n = 12) was assessed through comparison of ankle dorsiflexion angles measured simultaneously with the IAROM device and an optoelectronic motion analysis system. Intertester reliability (n = 17) was assessed by 2 testers who took measurements within the same day. RESULTS: Validity testing demonstrated excellent agreement (intraclass correlation coefficient [ICC] values ranging from 0.95 to 0.98). Reliability testing demonstrated good to excellent intertester agreement (ICC values ranging from 0.90 to 0.95). The ICCs for ankle joint dorsiflexion stiffness were .71 and .85 for the knee in an extended and flexed position, respectively. CONCLUSION: The IAROM device provides valid and reliable measurement of ankle dorsiflexion ROM. The IAROM device also allows calculation of stiffness by measuring ROM at multiple torque levels, although the reliability of the measurement is not optimal.
KW - IAROM
KW - Joint
KW - Plantar flexors
KW - Stiffness
UR - http://www.scopus.com/inward/record.url?scp=79954455082&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79954455082&partnerID=8YFLogxK
U2 - 10.2519/jospt.2011.3397
DO - 10.2519/jospt.2011.3397
M3 - Article
C2 - 21460462
AN - SCOPUS:79954455082
SN - 0190-6011
VL - 41
SP - 274
EP - 280
JO - Journal of Orthopaedic and Sports Physical Therapy
JF - Journal of Orthopaedic and Sports Physical Therapy
IS - 4
ER -