T1 - A rapidly deployable individualized system for augmenting ventilator capacity
AU - Srinivasan, Shriya S.
AU - Ramadi, Khalil B.
AU - Vicario, Francesco
AU - Gwynne, Declan
AU - Hayward, Alison
AU - Lagier, David
AU - Langer, Robert
AU - Frassica, Joseph J.
AU - Baron, Rebecca M.
AU - Traverso, Giovanni
N1 - Publisher Copyright:
© 2020 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works. Distributed under a Creative Commons Attribution License 4.0 (CC BY).
PY - 2020/6/24
Y1 - 2020/6/24
N2 - Strategies to split ventilators to support multiple patients requiring ventilatory support have been proposed and used in emergency cases in which shortages of ventilators cannot otherwise be remedied by production or procurement strategies. However, the current approaches to ventilator sharing lack the ability to individualize ventilation to each patient, measure pulmonary mechanics, and accommodate rebalancing of the airflow when one patient improves or deteriorates, posing safety concerns to patients. Potential cross-contamination, lack of alarms, insufficient monitoring, and inability to adapt to sudden changes in patient status have prevented widespread acceptance of ventilator sharing. We have developed an individualized system for augmenting ventilator efficacy (iSAVE) as a rapidly deployable platform that uses a single ventilator to simultaneously and more safely support two individuals. The iSAVE enables individual-specific volume and pressure control and the rebalancing of ventilation in response to improvement or deterioration in an individual's respiratory status. The iSAVE incorporates mechanisms to measure pulmonary mechanics, mitigate cross-contamination and backflow, and accommodate sudden flow changes due to individual interdependencies within the respiratory circuit. We demonstrate these capacities through validation using closed- and open-circuit ventilators on linear test lungs. We show that the iSAVE can temporarily ventilate two pigs on one ventilator as efficaciously as each pig on its own ventilator. By leveraging off-the-shelf medical components, the iSAVE could rapidly expand the ventilation capacity of health care facilities during emergency situations such as pandemics.
AB - Strategies to split ventilators to support multiple patients requiring ventilatory support have been proposed and used in emergency cases in which shortages of ventilators cannot otherwise be remedied by production or procurement strategies. However, the current approaches to ventilator sharing lack the ability to individualize ventilation to each patient, measure pulmonary mechanics, and accommodate rebalancing of the airflow when one patient improves or deteriorates, posing safety concerns to patients. Potential cross-contamination, lack of alarms, insufficient monitoring, and inability to adapt to sudden changes in patient status have prevented widespread acceptance of ventilator sharing. We have developed an individualized system for augmenting ventilator efficacy (iSAVE) as a rapidly deployable platform that uses a single ventilator to simultaneously and more safely support two individuals. The iSAVE enables individual-specific volume and pressure control and the rebalancing of ventilation in response to improvement or deterioration in an individual's respiratory status. The iSAVE incorporates mechanisms to measure pulmonary mechanics, mitigate cross-contamination and backflow, and accommodate sudden flow changes due to individual interdependencies within the respiratory circuit. We demonstrate these capacities through validation using closed- and open-circuit ventilators on linear test lungs. We show that the iSAVE can temporarily ventilate two pigs on one ventilator as efficaciously as each pig on its own ventilator. By leveraging off-the-shelf medical components, the iSAVE could rapidly expand the ventilation capacity of health care facilities during emergency situations such as pandemics.
UR - http://www.scopus.com/inward/record.url?scp=85087110607&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85087110607&partnerID=8YFLogxK
U2 - 10.1126/scitranslmed.abb9401
DO - 10.1126/scitranslmed.abb9401
M3 - Article
C2 - 32424018
AN - SCOPUS:85087110607
SN - 1946-6234
VL - 12
JO - Science Translational Medicine
JF - Science Translational Medicine
IS - 549
M1 - eabb9401
ER -