TY - GEN
T1 - A Scalable Readout IC Based on Wideband Noise Cancelling for Full-Rate Scanning of High-Density Microelectrode Arrays
AU - Kim, Jinuk
AU - Shin, Hongseok
AU - Kweon, Soon Jae
AU - Lee, Seongwook
AU - Ha, Sohmyung
AU - Je, Minkyu
N1 - Funding Information:
Research supported in part by the DGIST RandD Program of the Ministry of Science and ICT, Korea, under Grant 21-IJRP-01 and in part by the Future Interconnect Technology Cluster Program of Samsung Electronics, Korea.
Publisher Copyright:
© 2021 IEEE.
PY - 2021
Y1 - 2021
N2 - This paper presents a highly scalable readout IC for high-density microelectrode arrays (MEAs). Although the recent development of large-scale high-density MEAs provides opportunities to achieve sub-cellular neural recording over a wide network area, it is challenging to implement the readout IC that can operate with such MEAs. The requirement of high-speed recording in large-scale arrays induces wideband-noise folding, which makes it challenging to achieve a good noise performance for high-fidelity neural recording. Moreover, for the wideband readout, the major noise contributor changes from the readout circuit to the cell-electrode interface. In this paper, we first show why the interface noise becomes the dominant noise source and elucidate its component that contributes the most: sealing resistance. Then, we propose a new readout circuit structure, which can effectively cancel the wideband interface noise. As a result, the signal-to-noise ratio of input neural spike signals is improved dramatically in all cell-attachment or sealing conditions. Particularly, it is shown that under weakly sealed conditions, the spikes can be detected only when the proposed wideband noise cancellation technique is applied.
AB - This paper presents a highly scalable readout IC for high-density microelectrode arrays (MEAs). Although the recent development of large-scale high-density MEAs provides opportunities to achieve sub-cellular neural recording over a wide network area, it is challenging to implement the readout IC that can operate with such MEAs. The requirement of high-speed recording in large-scale arrays induces wideband-noise folding, which makes it challenging to achieve a good noise performance for high-fidelity neural recording. Moreover, for the wideband readout, the major noise contributor changes from the readout circuit to the cell-electrode interface. In this paper, we first show why the interface noise becomes the dominant noise source and elucidate its component that contributes the most: sealing resistance. Then, we propose a new readout circuit structure, which can effectively cancel the wideband interface noise. As a result, the signal-to-noise ratio of input neural spike signals is improved dramatically in all cell-attachment or sealing conditions. Particularly, it is shown that under weakly sealed conditions, the spikes can be detected only when the proposed wideband noise cancellation technique is applied.
KW - Microelectrodes
KW - Signal-To-Noise Ratio
UR - http://www.scopus.com/inward/record.url?scp=85122491766&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85122491766&partnerID=8YFLogxK
U2 - 10.1109/EMBC46164.2021.9630796
DO - 10.1109/EMBC46164.2021.9630796
M3 - Conference contribution
C2 - 34892794
AN - SCOPUS:85122491766
VL - 2021
T3 - Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
SP - 7344
EP - 7347
BT - 43rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2021
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 43rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2021
Y2 - 1 November 2021 through 5 November 2021
ER -