TY - GEN
T1 - Approaches to creating and controlling motion in MRI
AU - Fischer, Gregory S.
AU - Cole, Gregory
AU - Su, Hao
PY - 2011
Y1 - 2011
N2 - Magnetic Resonance Imaging (MRI) can provide three dimensional (3D) imaging with excellent resolution and sensitivity making it ideal for guiding and monitoring interventions. The development of MRI-compatible interventional devices is complicated by factors including: the high magnetic field strength, the requirement that such devices should not degrade image quality, and the confined physical space of the scanner bore. Numerous MRI guided actuated devices have been developed or are currently being developed utilizing piezoelectric actuators as their primary means of mechanical energy generation to enable better interventional procedure performance. While piezoelectric actuators are highly desirable for MRI guided actuation for their precision, high holding force, and non-magnetic operation they are often found to cause image degradation on a large enough to scale to render live imaging unusable. This paper describes a newly developed piezoelectric actuator driver and control system designed to drive a variety of both harmonic and non-harmonic motors that has been demonstrated to be capable of operating both harmonic and non-harmonic piezoelectric actuators with less than 5% SNR loss under closed loop control. The proposed system device allows for a single controller to control any supported actuator and feedback sensor without any physical hardware changes.
AB - Magnetic Resonance Imaging (MRI) can provide three dimensional (3D) imaging with excellent resolution and sensitivity making it ideal for guiding and monitoring interventions. The development of MRI-compatible interventional devices is complicated by factors including: the high magnetic field strength, the requirement that such devices should not degrade image quality, and the confined physical space of the scanner bore. Numerous MRI guided actuated devices have been developed or are currently being developed utilizing piezoelectric actuators as their primary means of mechanical energy generation to enable better interventional procedure performance. While piezoelectric actuators are highly desirable for MRI guided actuation for their precision, high holding force, and non-magnetic operation they are often found to cause image degradation on a large enough to scale to render live imaging unusable. This paper describes a newly developed piezoelectric actuator driver and control system designed to drive a variety of both harmonic and non-harmonic motors that has been demonstrated to be capable of operating both harmonic and non-harmonic piezoelectric actuators with less than 5% SNR loss under closed loop control. The proposed system device allows for a single controller to control any supported actuator and feedback sensor without any physical hardware changes.
UR - http://www.scopus.com/inward/record.url?scp=84864584222&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84864584222&partnerID=8YFLogxK
U2 - 10.1109/IEMBS.2011.6091649
DO - 10.1109/IEMBS.2011.6091649
M3 - Conference contribution
C2 - 22255873
AN - SCOPUS:84864584222
SN - 9781424441211
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 6687
EP - 6690
BT - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
T2 - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
Y2 - 30 August 2011 through 3 September 2011