Calculation of pad cross-talk in a thin-gap multiwire detector with pad readout

A. I. Mincer, N. Z. Lupu, Y. Rozen, S. Tarem, D. Lazic, S. Dado, J. J. Goldberg, G. Bella, L. Levinson, G. Mikenberg

    Research output: Contribution to journalArticlepeer-review

    Abstract

    Mechanisms responsible for cross-talk in a thin-gap multiwire chamber with pad readout are discussed. Using a simple capacitive coupling model, the cross-talk is calculated as a function of chamber geometry, capacitances and charge integration time. Calculation results are compared and found to be in reasonable agreement with measurements. Suggestions are given for reducing cross-talk in such a chamber.

    Original languageEnglish (US)
    Pages (from-to)41-50
    Number of pages10
    JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    Volume404
    Issue number1
    DOIs
    StatePublished - Feb 11 1998

    Keywords

    • Cross-talk
    • Thin-gap chamber

    ASJC Scopus subject areas

    • Nuclear and High Energy Physics
    • Instrumentation

    Fingerprint

    Dive into the research topics of 'Calculation of pad cross-talk in a thin-gap multiwire detector with pad readout'. Together they form a unique fingerprint.