TY - JOUR
T1 - Ceramic pressed to metal versus feldspathic porcelain fused to metal
T2 - A comparative study of bond strength
AU - Venkatachalam, Bhavani
AU - Goldstein, Gary R.
AU - Pines, Mitchell S.
AU - Hittelman, Eugene L.
PY - 2009
Y1 - 2009
N2 - Purpose: The aim of this study was to compare the debond/crack initiation strength (D/CIS) of a leucite-based low-fusing ceramic pressed (PC) to metal and feldspathic porcelain (FP) fused to metal. Materials and Methods: Forty rectangular metal specimens, 20 noble alloy (NA; gold-palladium) and 20 base metal alloy (BA; cobalt- chromium) were fabricated per ISO 9693:1999 standards (25.0 mm x 0.5 mm x 3.0 mm). Ten samples in each group received FP and the r10 received PC. The samples in the PC group underwent wax pattern build-ups and subsequent investing and casting. The ceramic dimensions in all four groups were 8.0 mm x 1.0 mm x 3.0 mm. The final metal-ceramic specimen thickness was 1.5 mm. All specimens were subject to the Schwickerath crack-initiation three-point bending test at a crosshead speed of 1.5 mm/min. Metal-ceramic fracture loads were recorded in Newtons and D/CIS was calculated using the formula: T b = k x× Ffail. Results: Mean D/CIS were as follows: BA-FP: 36.11 ±2.31 MPa, NA-FP: 42.64 ±1.94 MPa, BA-PC: 37.47 ±6.02 MPa, and NA-PC: 47.94 ±3.92 MPa. A 2-way ANOVA revealed no significant difference in D/CIS values between the four groups. A statistically significant difference was noted when comparing the mean D/CIS values obtained between the two metal alloys used (NA: 45.29 MPa and BA: 36.79 MPa). Conclusion: No differences (P > .05) in mean D/CIS were found between the low-fusing ceramic pressed to metal and the FP fused to metal. A higher mean D/CIS (P > .05) was found for the NA compared to the BA, with both ceramics tested.
AB - Purpose: The aim of this study was to compare the debond/crack initiation strength (D/CIS) of a leucite-based low-fusing ceramic pressed (PC) to metal and feldspathic porcelain (FP) fused to metal. Materials and Methods: Forty rectangular metal specimens, 20 noble alloy (NA; gold-palladium) and 20 base metal alloy (BA; cobalt- chromium) were fabricated per ISO 9693:1999 standards (25.0 mm x 0.5 mm x 3.0 mm). Ten samples in each group received FP and the r10 received PC. The samples in the PC group underwent wax pattern build-ups and subsequent investing and casting. The ceramic dimensions in all four groups were 8.0 mm x 1.0 mm x 3.0 mm. The final metal-ceramic specimen thickness was 1.5 mm. All specimens were subject to the Schwickerath crack-initiation three-point bending test at a crosshead speed of 1.5 mm/min. Metal-ceramic fracture loads were recorded in Newtons and D/CIS was calculated using the formula: T b = k x× Ffail. Results: Mean D/CIS were as follows: BA-FP: 36.11 ±2.31 MPa, NA-FP: 42.64 ±1.94 MPa, BA-PC: 37.47 ±6.02 MPa, and NA-PC: 47.94 ±3.92 MPa. A 2-way ANOVA revealed no significant difference in D/CIS values between the four groups. A statistically significant difference was noted when comparing the mean D/CIS values obtained between the two metal alloys used (NA: 45.29 MPa and BA: 36.79 MPa). Conclusion: No differences (P > .05) in mean D/CIS were found between the low-fusing ceramic pressed to metal and the FP fused to metal. A higher mean D/CIS (P > .05) was found for the NA compared to the BA, with both ceramics tested.
UR - http://www.scopus.com/inward/record.url?scp=65549150845&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=65549150845&partnerID=8YFLogxK
M3 - Article
C2 - 19260436
AN - SCOPUS:65549150845
SN - 0893-2174
VL - 22
SP - 94
EP - 100
JO - International Journal of Prosthodontics
JF - International Journal of Prosthodontics
IS - 1
ER -