TY - JOUR
T1 - Characterization of five different implant surfaces and their effect on osseointegration
T2 - A study in dogs
AU - Coelho, Paulo G.
AU - Bonfante, Estevam A.
AU - Pessoa, Roberto S.
AU - Marin, Charles
AU - Granato, Rodrigo
AU - Giro, Gabriela
AU - Witek, Lukasz
AU - Suzuki, Marcelo
PY - 2011/5
Y1 - 2011/5
N2 - Background: Chemical modification of implant surface is typically associated with surface topographic alterations that may affect early osseointegration. This study investigates the effects of controlled surface alterations in early osseointegration in an animal model. Methods: Five implant surfaces were evaluated: 1) aluminablasting, 2) biologic blasting, 3) plasma, 4) microblasted resorbable blasting media (microblasted RBM), and 5) alumina-blasting/acid-etched (AB/AE). Surface topography was characterized by scanning electron microscopy and optical interferometry, and chemical assessment by x-ray photoelectron spectroscopy. The implants were placed in the radius of six dogs, remaining 2 and 4 weeks in vivo. After euthanization, specimens were torqued-to-interface failure and nondecalcified-processed for histomorphologic bone-implant contact, and bone area fraction-occupied evaluation. Statistical evaluation was performed by one-way analysis of variance (P <0.05) and post hoc testing by the Tukey test. Results: The alumina-blasting surface presented the highest average surface roughness and mean root square of the surface values, the biologic blasting the lowest, and AB/AE an intermediate value. The remaining surfaces presented intermediate values between the biologic blasting and AB/AE. The x-ray photoelectron spectroscopy spectra revealed calcium and phosphorus for the biologic blasting and microblasted RBM surfaces, and the highest oxygen levels for the plasma, microblasted RBM, and AB/AE surfaces. Significantly higher torque was observed at 2 weeks for the microblasted RBM surface (P <0.04), but no differences existed between surfaces at 4 weeks (P >0.74). No significant differences in bone-implant contact and bone area fraction-occupied values were observed at 2 and 4 weeks. Conclusion: The five surfaces were osteoconductive and resulted in high degrees of osseointegration and biomechanical fixation.
AB - Background: Chemical modification of implant surface is typically associated with surface topographic alterations that may affect early osseointegration. This study investigates the effects of controlled surface alterations in early osseointegration in an animal model. Methods: Five implant surfaces were evaluated: 1) aluminablasting, 2) biologic blasting, 3) plasma, 4) microblasted resorbable blasting media (microblasted RBM), and 5) alumina-blasting/acid-etched (AB/AE). Surface topography was characterized by scanning electron microscopy and optical interferometry, and chemical assessment by x-ray photoelectron spectroscopy. The implants were placed in the radius of six dogs, remaining 2 and 4 weeks in vivo. After euthanization, specimens were torqued-to-interface failure and nondecalcified-processed for histomorphologic bone-implant contact, and bone area fraction-occupied evaluation. Statistical evaluation was performed by one-way analysis of variance (P <0.05) and post hoc testing by the Tukey test. Results: The alumina-blasting surface presented the highest average surface roughness and mean root square of the surface values, the biologic blasting the lowest, and AB/AE an intermediate value. The remaining surfaces presented intermediate values between the biologic blasting and AB/AE. The x-ray photoelectron spectroscopy spectra revealed calcium and phosphorus for the biologic blasting and microblasted RBM surfaces, and the highest oxygen levels for the plasma, microblasted RBM, and AB/AE surfaces. Significantly higher torque was observed at 2 weeks for the microblasted RBM surface (P <0.04), but no differences existed between surfaces at 4 weeks (P >0.74). No significant differences in bone-implant contact and bone area fraction-occupied values were observed at 2 and 4 weeks. Conclusion: The five surfaces were osteoconductive and resulted in high degrees of osseointegration and biomechanical fixation.
KW - Animal
KW - Bone
KW - Dental implant
KW - Histology
KW - Osseointegration
KW - Torque
UR - http://www.scopus.com/inward/record.url?scp=79955592272&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79955592272&partnerID=8YFLogxK
U2 - 10.1902/jop.2010.100520
DO - 10.1902/jop.2010.100520
M3 - Article
C2 - 21054223
AN - SCOPUS:79955592272
SN - 0022-3492
VL - 82
SP - 742
EP - 750
JO - Journal of periodontology
JF - Journal of periodontology
IS - 5
ER -