TY - JOUR
T1 - Evaluating pulsatile ocular blood flow analysis in normal and treated glaucomatous eyes
AU - Aydin, Ali
AU - Wollstein, Gadi
AU - Price, Lori Lyn
AU - Schuman, Joel S.
PY - 2003/9/1
Y1 - 2003/9/1
N2 - PURPOSE: To evaluate pulsatile ocular blood flow (POBF) analysis in normal subjects and glaucoma patients by comparison of POBF measurements with functional (as determined by visual field [VF]) and structural (as determined by optical coherence tomography [OCT]) measures. DESIGN: Prospective, cross-sectional study. METHODS: Forty-one eyes of 24 consecutive glaucoma patients and 20 eyes of 10 healthy subjects were studied; POBF analysis was performed on all subjects at the same visit as VF testing and OCT retinal nerve fiber layer (NFL) thickness measurement. The mean results of normal and glaucomatous eyes were compared for each method. Correlation between measurements obtained with each modality and the discriminating power using receiver operator characteristic curves was tested. RESULTS: The mean POBF (standard deviation [SD]) in the normal group was 1,010.4 (292.8) μl/min and 989.3 (305.5) μl/min in the glaucoma group (P = .90). Significant differences between groups were found for VF mean deviation and pattern standard deviation (P = .02, P = .004, respectively) and OCT mean NFL thickness (P < .0001). No correlation was found between POBF parameters and intraocular pressure, VF, or OCT variables except for intraocular pressure in glaucoma group (r = -.43, P = .003). The area under the receiver operator characteristic curves was higher for VF indexes and OCT mean NFL thickness than POBF parameters for distinguishing between normal and glaucomatous eyes. CONCLUSIONS: The wide range of normal values and the low discriminating power of POBF between normal and glaucomatous eyes limits the clinical use of the device for glaucoma patients.
AB - PURPOSE: To evaluate pulsatile ocular blood flow (POBF) analysis in normal subjects and glaucoma patients by comparison of POBF measurements with functional (as determined by visual field [VF]) and structural (as determined by optical coherence tomography [OCT]) measures. DESIGN: Prospective, cross-sectional study. METHODS: Forty-one eyes of 24 consecutive glaucoma patients and 20 eyes of 10 healthy subjects were studied; POBF analysis was performed on all subjects at the same visit as VF testing and OCT retinal nerve fiber layer (NFL) thickness measurement. The mean results of normal and glaucomatous eyes were compared for each method. Correlation between measurements obtained with each modality and the discriminating power using receiver operator characteristic curves was tested. RESULTS: The mean POBF (standard deviation [SD]) in the normal group was 1,010.4 (292.8) μl/min and 989.3 (305.5) μl/min in the glaucoma group (P = .90). Significant differences between groups were found for VF mean deviation and pattern standard deviation (P = .02, P = .004, respectively) and OCT mean NFL thickness (P < .0001). No correlation was found between POBF parameters and intraocular pressure, VF, or OCT variables except for intraocular pressure in glaucoma group (r = -.43, P = .003). The area under the receiver operator characteristic curves was higher for VF indexes and OCT mean NFL thickness than POBF parameters for distinguishing between normal and glaucomatous eyes. CONCLUSIONS: The wide range of normal values and the low discriminating power of POBF between normal and glaucomatous eyes limits the clinical use of the device for glaucoma patients.
UR - http://www.scopus.com/inward/record.url?scp=0041826861&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0041826861&partnerID=8YFLogxK
U2 - 10.1016/S0002-9394(03)00237-X
DO - 10.1016/S0002-9394(03)00237-X
M3 - Article
C2 - 12967797
AN - SCOPUS:0041826861
SN - 0002-9394
VL - 136
SP - 448
EP - 453
JO - American Journal of Ophthalmology
JF - American Journal of Ophthalmology
IS - 3
ER -