TY - JOUR
T1 - Evaluation of coriolis mass flow meters under real-life operating conditions
AU - Obradovic, D. B.
AU - Vradis, G. C.
AU - Otugen, M. V.
PY - 1996
Y1 - 1996
N2 - The performance of Coriolis mass flow meters subjected to external vibrations similar to those encountered in field operations was studied experimentally. The two models of the mass flow meters studied were from a single manufacturer which are extensively used in high pressure gas applications. The working fluid used was air. The range of parameters studied, the mass flow rate, gas pressure and vibrational frequencies, correspond to those experienced by such flow meters under realistic working condition in Natural Gas Vehicle (NGV) filling stations, as determined through an on-site monitoring program of NGV fueling stations.
AB - The performance of Coriolis mass flow meters subjected to external vibrations similar to those encountered in field operations was studied experimentally. The two models of the mass flow meters studied were from a single manufacturer which are extensively used in high pressure gas applications. The working fluid used was air. The range of parameters studied, the mass flow rate, gas pressure and vibrational frequencies, correspond to those experienced by such flow meters under realistic working condition in Natural Gas Vehicle (NGV) filling stations, as determined through an on-site monitoring program of NGV fueling stations.
UR - http://www.scopus.com/inward/record.url?scp=0030359933&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030359933&partnerID=8YFLogxK
M3 - Review article
AN - SCOPUS:0030359933
SN - 0888-8116
VL - 239
SP - 421
EP - 426
JO - American Society of Mechanical Engineers, Fluids Engineering Division (Publication) FED
JF - American Society of Mechanical Engineers, Fluids Engineering Division (Publication) FED
ER -