TY - GEN
T1 - From Unstable Electrode Contacts to Reliable Control
T2 - 2024 IEEE International Conference on Robotics and Automation, ICRA 2024
AU - Tyacke, Eion
AU - Gupta, Kunal
AU - Patel, Jay
AU - Katoch, Raghav
AU - Atashzar, S. Farokh
N1 - Publisher Copyright:
© 2024 IEEE.
PY - 2024
Y1 - 2024
N2 - In the past decade, there has been significant advancement in designing wearable neural interfaces for controlling neurorobotic systems, particularly bionic limbs. These interfaces function by decoding signals captured noninvasively from the skin's surface. Portable high-density surface electromyography (HD-sEMG) modules combined with deep learning decoding have attracted interest by achieving excellent gesture prediction and myoelectric control of prosthetic systems and neurorobots. However, factors like small electrode size and unstable electrode-skin contacts make HD-sEMG susceptible to pixel electrode drops. The sparse electrode-skin disconnections rooted in issues such as low adhesion, sweating, hair blockage, and skin stretch challenge the reliability and scalability of these modules as the perception unit for neurorobotic systems. This paper proposes a novel deep-learning model providing resiliency for HD-sEMG modules, which can be used in the wearable interfaces of neurorobots. The proposed 3D Dilated Efficient CapsNet model trains on an augmented input space to computationally 'force' the network to learn channel dropout variations and thus learn robustness to channel dropout. The proposed framework maintained high performance under a sensor dropout reliability study conducted. Results show conventional models' performance significantly degrades with dropout and is recovered using the proposed architecture and the training paradigm.
AB - In the past decade, there has been significant advancement in designing wearable neural interfaces for controlling neurorobotic systems, particularly bionic limbs. These interfaces function by decoding signals captured noninvasively from the skin's surface. Portable high-density surface electromyography (HD-sEMG) modules combined with deep learning decoding have attracted interest by achieving excellent gesture prediction and myoelectric control of prosthetic systems and neurorobots. However, factors like small electrode size and unstable electrode-skin contacts make HD-sEMG susceptible to pixel electrode drops. The sparse electrode-skin disconnections rooted in issues such as low adhesion, sweating, hair blockage, and skin stretch challenge the reliability and scalability of these modules as the perception unit for neurorobotic systems. This paper proposes a novel deep-learning model providing resiliency for HD-sEMG modules, which can be used in the wearable interfaces of neurorobots. The proposed 3D Dilated Efficient CapsNet model trains on an augmented input space to computationally 'force' the network to learn channel dropout variations and thus learn robustness to channel dropout. The proposed framework maintained high performance under a sensor dropout reliability study conducted. Results show conventional models' performance significantly degrades with dropout and is recovered using the proposed architecture and the training paradigm.
UR - http://www.scopus.com/inward/record.url?scp=85202448640&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85202448640&partnerID=8YFLogxK
U2 - 10.1109/ICRA57147.2024.10610638
DO - 10.1109/ICRA57147.2024.10610638
M3 - Conference contribution
AN - SCOPUS:85202448640
T3 - Proceedings - IEEE International Conference on Robotics and Automation
SP - 7874
EP - 7879
BT - 2024 IEEE International Conference on Robotics and Automation, ICRA 2024
PB - Institute of Electrical and Electronics Engineers Inc.
Y2 - 13 May 2024 through 17 May 2024
ER -