Abstract
We present the results of tests made on two types of uranium/liquid argon calorimeter modules, one electromagnetic and one hadronic, constructed for the D0 detector at the Fermilab Tevatron Collider. For electrons and hadrons with energies between 10 and 150 GeV, we present measurements of energy resolution, linearity of response, electromagnetic to hadronic response ratio ( e π), and longitudinal hadronic shower development. We have also investigated the effects of adding small amounts of methane to the liquid argon.
Original language | English (US) |
---|---|
Pages (from-to) | 36-44 |
Number of pages | 9 |
Journal | Nuclear Inst. and Methods in Physics Research, A |
Volume | 280 |
Issue number | 1 |
DOIs | |
State | Published - Aug 1 1989 |
ASJC Scopus subject areas
- Nuclear and High Energy Physics
- Instrumentation