T1 - High-Speed Atomic Force Microscopy Revealing Contamination in DNA Purification Systems
AU - Mikheikin, Andrey
AU - Olsen, Anita
AU - Picco, Loren
AU - Payton, Oliver
AU - Mishra, Bud
AU - Gimzewski, James K.
AU - Reed, Jason
N1 - Funding Information:
Funding for this work was provided by National Institutes of Health Grant R01GM094388 to J.R., B.M., and J.K.G.
Publisher Copyright:
© 2016 American Chemical Society.
PY - 2016/3/1
Y1 - 2016/3/1
N2 - Motivated by reports of low-level DNA contamination in popular commercial DNA purification kits, we employed a novel high-speed atomic force microscopy (HS-AFM) method to detect and characterize particulate and polymeric contaminants in four such systems: Qiagen MinElute PCR Purification, Zymo Research DNA Clean and Concentrator-5, Invitrogen ChargeSwitch-Pro PCR Purification, and Beckman Coulter AMPure XP. HS-AFM avoids amplification artifacts present in PCR or in the sequencing of amplified products, and it requires no chemical labels and easily achieves near-single-molecule sensitivity. Using this technique, we found trace levels of filamentous contamination, similar in appearance to dsDNA, in eluates from the Zymo, Qiagen, and ChargeSwitch kits. Conversely, we detected no contaminants in magnetic bead-based AMPure XP solutions. Eluates from the Zymo kits also tested positive for DNA in fluorescent intercalator dye and whole genome amplification (WGA) assays. Qiagen kits tested positive in the fluorescence assay but negative in the WGA assay. Both ChargeSwitch and AMPure XP tested negative in the fluorescence assay while the WGA results for these two kits were ambiguous. Taken together, our findings suggest AMPure XP would be the best choice for analyses requiring very high analytical stringency. While HS-AFM alone does not provide chemical specificity, it is a potentially valuable tool for characterizing and quantifying trace contaminants in molecular biology reagents and instruments in cases where conventional techniques fail.
AB - Motivated by reports of low-level DNA contamination in popular commercial DNA purification kits, we employed a novel high-speed atomic force microscopy (HS-AFM) method to detect and characterize particulate and polymeric contaminants in four such systems: Qiagen MinElute PCR Purification, Zymo Research DNA Clean and Concentrator-5, Invitrogen ChargeSwitch-Pro PCR Purification, and Beckman Coulter AMPure XP. HS-AFM avoids amplification artifacts present in PCR or in the sequencing of amplified products, and it requires no chemical labels and easily achieves near-single-molecule sensitivity. Using this technique, we found trace levels of filamentous contamination, similar in appearance to dsDNA, in eluates from the Zymo, Qiagen, and ChargeSwitch kits. Conversely, we detected no contaminants in magnetic bead-based AMPure XP solutions. Eluates from the Zymo kits also tested positive for DNA in fluorescent intercalator dye and whole genome amplification (WGA) assays. Qiagen kits tested positive in the fluorescence assay but negative in the WGA assay. Both ChargeSwitch and AMPure XP tested negative in the fluorescence assay while the WGA results for these two kits were ambiguous. Taken together, our findings suggest AMPure XP would be the best choice for analyses requiring very high analytical stringency. While HS-AFM alone does not provide chemical specificity, it is a potentially valuable tool for characterizing and quantifying trace contaminants in molecular biology reagents and instruments in cases where conventional techniques fail.
UR - http://www.scopus.com/inward/record.url?scp=84960146077&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84960146077&partnerID=8YFLogxK
U2 - 10.1021/acs.analchem.5b04023
DO - 10.1021/acs.analchem.5b04023
M3 - Letter
C2 - 26878668
AN - SCOPUS:84960146077
SN - 0003-2700
VL - 88
SP - 2527
EP - 2532
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 5
ER -