TY - JOUR
T1 - Improving consensus scoring of crowdsourced data using the rasch model
T2 - Development and refinement of a diagnostic instrument
AU - Brady, Christopher John
AU - Mudie, Lucy Iluka
AU - Wang, Xueyang
AU - Guallar, Eliseo
AU - Friedman, David Steven
PY - 2017
Y1 - 2017
N2 - Background: Diabetic retinopathy (DR) is a leading cause of vision loss in working age individuals worldwide. While screening is effective and cost effective, it remains underutilized, and novel methods are needed to increase detection of DR. This clinical validation study compared diagnostic gradings of retinal fundus photographs provided by volunteers on the Amazon Mechanical Turk (AMT) crowdsourcing marketplace with expert-provided gold-standard grading and explored whether determination of the consensus of crowdsourced classifications could be improved beyond a simple majority vote (MV) using regression methods. Objective: The aim of our study was to determine whether regression methods could be used to improve the consensus grading of data collected by crowdsourcing. Methods: A total of 1200 retinal images of individuals with diabetes mellitus from the Messidor public dataset were posted to AMT. Eligible crowdsourcing workers had at least 500 previously approved tasks with an approval rating of 99% across their prior submitted work. A total of 10 workers were recruited to classify each image as normal or abnormal. If half or more workers judged the image to be abnormal, the MV consensus grade was recorded as abnormal. Rasch analysis was then used to calculate worker ability scores in a random 50% training set, which were then used as weights in a regression model in the remaining 50% test set to determine if a more accurate consensus could be devised. Outcomes of interest were the percent correctly classified images, sensitivity, specificity, and area under the receiver operating characteristic (AUROC) for the consensus grade as compared with the expert grading provided with the dataset. Results: Using MV grading, the consensus was correct in 75.5% of images (906/1200), with 75.5% sensitivity, 75.5% specificity, and an AUROC of 0.75 (95% CI 0.73-0.78). A logistic regression model using Rasch-weighted individual scores generated an AUROC of 0.91 (95% CI 0.88-0.93) compared with 0.89 (95% CI 0.86-92) for a model using unweighted scores (chi-square P value<.001). Setting a diagnostic cut-point to optimize sensitivity at 90%, 77.5% (465/600) were graded correctly, with 90.3% sensitivity, 68.5% specificity, and an AUROC of 0.79 (95% CI 0.76-0.83). Conclusions: Crowdsourced interpretations of retinal images provide rapid and accurate results as compared with a gold-standard grading. Creating a logistic regression model using Rasch analysis to weight crowdsourced classifications by worker ability improves accuracy of aggregated grades as compared with simple majority vote.
AB - Background: Diabetic retinopathy (DR) is a leading cause of vision loss in working age individuals worldwide. While screening is effective and cost effective, it remains underutilized, and novel methods are needed to increase detection of DR. This clinical validation study compared diagnostic gradings of retinal fundus photographs provided by volunteers on the Amazon Mechanical Turk (AMT) crowdsourcing marketplace with expert-provided gold-standard grading and explored whether determination of the consensus of crowdsourced classifications could be improved beyond a simple majority vote (MV) using regression methods. Objective: The aim of our study was to determine whether regression methods could be used to improve the consensus grading of data collected by crowdsourcing. Methods: A total of 1200 retinal images of individuals with diabetes mellitus from the Messidor public dataset were posted to AMT. Eligible crowdsourcing workers had at least 500 previously approved tasks with an approval rating of 99% across their prior submitted work. A total of 10 workers were recruited to classify each image as normal or abnormal. If half or more workers judged the image to be abnormal, the MV consensus grade was recorded as abnormal. Rasch analysis was then used to calculate worker ability scores in a random 50% training set, which were then used as weights in a regression model in the remaining 50% test set to determine if a more accurate consensus could be devised. Outcomes of interest were the percent correctly classified images, sensitivity, specificity, and area under the receiver operating characteristic (AUROC) for the consensus grade as compared with the expert grading provided with the dataset. Results: Using MV grading, the consensus was correct in 75.5% of images (906/1200), with 75.5% sensitivity, 75.5% specificity, and an AUROC of 0.75 (95% CI 0.73-0.78). A logistic regression model using Rasch-weighted individual scores generated an AUROC of 0.91 (95% CI 0.88-0.93) compared with 0.89 (95% CI 0.86-92) for a model using unweighted scores (chi-square P value<.001). Setting a diagnostic cut-point to optimize sensitivity at 90%, 77.5% (465/600) were graded correctly, with 90.3% sensitivity, 68.5% specificity, and an AUROC of 0.79 (95% CI 0.76-0.83). Conclusions: Crowdsourced interpretations of retinal images provide rapid and accurate results as compared with a gold-standard grading. Creating a logistic regression model using Rasch analysis to weight crowdsourced classifications by worker ability improves accuracy of aggregated grades as compared with simple majority vote.
KW - Amazon Mechanical Turk
KW - Crowdsourcing
KW - Diabetic retinopathy
KW - Rasch analysis
UR - http://www.scopus.com/inward/record.url?scp=85021816133&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85021816133&partnerID=8YFLogxK
U2 - 10.2196/jmir.7984
DO - 10.2196/jmir.7984
M3 - Article
C2 - 28634154
AN - SCOPUS:85021816133
SN - 1439-4456
VL - 19
JO - Journal of medical Internet research
JF - Journal of medical Internet research
IS - 6
M1 - e222
ER -