TY - JOUR
T1 - Inverse correlations between wear and mechanical properties in biphasic dental materials with ceramic constituents
AU - Borrero-Lopez, Oscar
AU - Guiberteau, Fernando
AU - Zhang, Yu
AU - Lawn, Brian R.
N1 - Publisher Copyright:
© 2020 Elsevier Ltd
PY - 2020/5
Y1 - 2020/5
N2 - The objective of this study is to elucidate the interdependence of competing mechanical degradation processes in biphasic dental materials with ceramic constituents in the region of high-pressure occlusal loading. It is hypothesized that wear resistance in this region correlates inversely with basic material parameters (modulus, hardness, toughness, strength) evaluated from 'standardized' test specimens. Ball-on-flat wear tests in simulation of oral function are used to quantify susceptibility to protracted sliding contact damage. Wear rates for this class of dental material tend to increase with quasistatic parameter values, so the latter do not provide a reliable guide to longevity. The generation of severe-wear facets involves cumulative quasiplastic deformation and microcrack coalescence at the grain level. It is implied that interplay between wear and fracture mechanisms should be an important consideration in future microstructural design of dental ceramics, especially in the quest to balance durability against esthetics.
AB - The objective of this study is to elucidate the interdependence of competing mechanical degradation processes in biphasic dental materials with ceramic constituents in the region of high-pressure occlusal loading. It is hypothesized that wear resistance in this region correlates inversely with basic material parameters (modulus, hardness, toughness, strength) evaluated from 'standardized' test specimens. Ball-on-flat wear tests in simulation of oral function are used to quantify susceptibility to protracted sliding contact damage. Wear rates for this class of dental material tend to increase with quasistatic parameter values, so the latter do not provide a reliable guide to longevity. The generation of severe-wear facets involves cumulative quasiplastic deformation and microcrack coalescence at the grain level. It is implied that interplay between wear and fracture mechanisms should be an important consideration in future microstructural design of dental ceramics, especially in the quest to balance durability against esthetics.
KW - Biphasic dental ceramics
KW - Fracture
KW - Mechanical properties
KW - Microstructure
KW - Wear
UR - http://www.scopus.com/inward/record.url?scp=85081988705&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85081988705&partnerID=8YFLogxK
U2 - 10.1016/j.jmbbm.2020.103722
DO - 10.1016/j.jmbbm.2020.103722
M3 - Article
C2 - 32279844
AN - SCOPUS:85081988705
SN - 1751-6161
VL - 105
JO - Journal of the Mechanical Behavior of Biomedical Materials
JF - Journal of the Mechanical Behavior of Biomedical Materials
M1 - 103722
ER -