TY - JOUR
T1 - Marginal and internal adaptation of zirconia crowns
T2 - A comparative study of assessment methods
AU - Cunali, Rafael Schlögel
AU - Saab, Rafaella Caramori
AU - Correr, Gisele Maria
AU - Da Cunha, Leonardo Fernandes
AU - Ornaghi, Bárbara Pick
AU - Ritter, André V.
AU - Gonzaga, Carla Castiglia
N1 - Publisher Copyright:
© 2017, Associacao Brasileira de Divulgacao Cientifica. All rights reserved.
PY - 2017/7/1
Y1 - 2017/7/1
N2 - Marginal and internal adaptation is critical for the success of indirect restorations. New imaging systems make it possible to evaluate these parameters with precision and non-destructively. This study evaluated the marginal and internal adaptation of zirconia copings fabricated with two different systems using both silicone replica and microcomputed tomography (micro-CT) assessment methods. A metal master model, representing a preparation for an all-ceramic full crown, was digitally scanned and polycrystalline zirconia copings were fabricated with either Ceramill Zi (Amann-Girrbach) or inCoris Zi (Dentslpy-Sirona), n=10. For each coping, marginal and internal gaps were evaluated by silicone replica and micro-CT assessment methods. Four assessment points of each replica cross-section and micro-CT image were evaluated using imaging software: marginal gap (MG), axial wall (AW), axio-occlusal angle (AO) and mid-occlusal wall (MO). Data were statistically analyzed by factorial ANOVA and Tukey test (α=0.05). There was no statistically significant difference between the methods for MG and AW. For AO, there were significant differences between methods for Amann copings, while for Dentsply-Sirona copings similar values were observed. For MO, both methods presented statistically significant differences. A positive correlation was observed determined by the two assessment methods for MG values. In conclusion, the assessment method influenced the evaluation of marginal and internal adaptation of zirconia copings. Micro-CT showed lower marginal and internal gap values when compared to the silicone replica technique, although the difference was not always statistically significant. Marginal gap and axial wall assessment points showed the lower gap values, regardless of ceramic system and assessment method used.
AB - Marginal and internal adaptation is critical for the success of indirect restorations. New imaging systems make it possible to evaluate these parameters with precision and non-destructively. This study evaluated the marginal and internal adaptation of zirconia copings fabricated with two different systems using both silicone replica and microcomputed tomography (micro-CT) assessment methods. A metal master model, representing a preparation for an all-ceramic full crown, was digitally scanned and polycrystalline zirconia copings were fabricated with either Ceramill Zi (Amann-Girrbach) or inCoris Zi (Dentslpy-Sirona), n=10. For each coping, marginal and internal gaps were evaluated by silicone replica and micro-CT assessment methods. Four assessment points of each replica cross-section and micro-CT image were evaluated using imaging software: marginal gap (MG), axial wall (AW), axio-occlusal angle (AO) and mid-occlusal wall (MO). Data were statistically analyzed by factorial ANOVA and Tukey test (α=0.05). There was no statistically significant difference between the methods for MG and AW. For AO, there were significant differences between methods for Amann copings, while for Dentsply-Sirona copings similar values were observed. For MO, both methods presented statistically significant differences. A positive correlation was observed determined by the two assessment methods for MG values. In conclusion, the assessment method influenced the evaluation of marginal and internal adaptation of zirconia copings. Micro-CT showed lower marginal and internal gap values when compared to the silicone replica technique, although the difference was not always statistically significant. Marginal gap and axial wall assessment points showed the lower gap values, regardless of ceramic system and assessment method used.
KW - CAD/CAM
KW - Dental prosthesis
KW - Marginal fit
KW - Zirconia
UR - http://www.scopus.com/inward/record.url?scp=85034417466&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85034417466&partnerID=8YFLogxK
U2 - 10.1590/0103-6440201601531
DO - 10.1590/0103-6440201601531
M3 - Article
C2 - 29160399
AN - SCOPUS:85034417466
SN - 0103-6440
VL - 28
SP - 467
EP - 473
JO - Brazilian Dental Journal
JF - Brazilian Dental Journal
IS - 4
ER -