TY - JOUR
T1 - Microtensile bond strength between glass ionomer cement and silver diamine fluoride-treated carious primary dentin
AU - Puwanawiroj, Aksrapak
AU - Trairatvorakul, Chutima
AU - Dasanayake, Ananda P.
AU - Auychai, Prim
PY - 2018/7/1
Y1 - 2018/7/1
N2 - Purpose: The study objectives were to investigate the effect of silver diamine fluoride (SDF) on the microtensile bond strength between glass ionomer cement and carious primary dentin and evaluate the mode of restoration failure. Methods: Forty carious primary molars were sectioned in half through the middle of the carious lesion and randomly allocated to test and control groups. The test specimens were treated with 38 percent SDF, and the control, deionized water. The samples were stored in artificial saliva for 14 days at 37 degrees Celsius, and the dentin surfaces were conditioned and restored with Fuji IX GP Extra. After 24 hours in artificial saliva, the specimens were prepared for microtensile bond strength testing and stressed in tension at one mm per minute until failure. Mean bond strengths were compared using the paired t test. The failure mode was assessed with a stereomicroscope under 40X magnification. Results: The mean microtensile strength for the test group was 7.4 MPa (SD=±5.1) and 6.3 (±4.6) for the control group (P>0.05). Most common failure mode was the mixed failure mode in both groups. Conclusion: Silver diamine fluoride does not adversely affect the bond strength between glass ionomer cement and carious primary dentin in vitro.
AB - Purpose: The study objectives were to investigate the effect of silver diamine fluoride (SDF) on the microtensile bond strength between glass ionomer cement and carious primary dentin and evaluate the mode of restoration failure. Methods: Forty carious primary molars were sectioned in half through the middle of the carious lesion and randomly allocated to test and control groups. The test specimens were treated with 38 percent SDF, and the control, deionized water. The samples were stored in artificial saliva for 14 days at 37 degrees Celsius, and the dentin surfaces were conditioned and restored with Fuji IX GP Extra. After 24 hours in artificial saliva, the specimens were prepared for microtensile bond strength testing and stressed in tension at one mm per minute until failure. Mean bond strengths were compared using the paired t test. The failure mode was assessed with a stereomicroscope under 40X magnification. Results: The mean microtensile strength for the test group was 7.4 MPa (SD=±5.1) and 6.3 (±4.6) for the control group (P>0.05). Most common failure mode was the mixed failure mode in both groups. Conclusion: Silver diamine fluoride does not adversely affect the bond strength between glass ionomer cement and carious primary dentin in vitro.
KW - Carious primary dentin
KW - Glass ionomer cement
KW - Silver diamine fluoride
UR - http://www.scopus.com/inward/record.url?scp=85051677305&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85051677305&partnerID=8YFLogxK
M3 - Article
C2 - 30345969
AN - SCOPUS:85051677305
SN - 0164-1263
VL - 40
SP - 291
EP - 295
JO - Pediatric dentistry
JF - Pediatric dentistry
IS - 4
ER -