N2 - Aim: To prospectively determine the incidence of nickel-titanium rotary instrument fracture in an endodontic clinical practice setting. Methodology: Eleven second year endodontic residents, using four nickel-titanium rotary instrument systems (ProFile, ProTaper, GTRotary and K3Endo) according to the recommendations of the manufacturers, instrumented 3181 canals in 1403 teeth of 1235 patients, in a dental school post-graduate endodontic clinic, in 1 year. The incidence of instrument fracture was determined based on the number of instruments used. When fracture occurred, data were collected concerning the type, size, taper and prior use of the fractured instruments, the length and location of the fragment within the root canal and the curvature of the canal. Results: The overall incidence of instrument fracture was 0.39%. The incidence of fracture for ProFile, ProTaper, GTRotary and K3Endo files was 0.28%, 0.41%, 0.39% and 0.52%, respectively. There was no statistically significant difference between instrument systems. The percentage of teeth in which instruments fractured was 1.9% (0.28% for anterior teeth, 1.56% for pre-molars and 2.74% for molars). A total of 26 instruments fractured, of which 23 had tapers of 0.06 or greater. Most of the fragments were located in the apical third of the root canal, and both the median and mode amongst the fragment lengths were 2 mm. Conclusions: The low incidence of nickel-titanium rotary instrument fracture supports the continued use of these instruments in root canal treatment.
AB - Aim: To prospectively determine the incidence of nickel-titanium rotary instrument fracture in an endodontic clinical practice setting. Methodology: Eleven second year endodontic residents, using four nickel-titanium rotary instrument systems (ProFile, ProTaper, GTRotary and K3Endo) according to the recommendations of the manufacturers, instrumented 3181 canals in 1403 teeth of 1235 patients, in a dental school post-graduate endodontic clinic, in 1 year. The incidence of instrument fracture was determined based on the number of instruments used. When fracture occurred, data were collected concerning the type, size, taper and prior use of the fractured instruments, the length and location of the fragment within the root canal and the curvature of the canal. Results: The overall incidence of instrument fracture was 0.39%. The incidence of fracture for ProFile, ProTaper, GTRotary and K3Endo files was 0.28%, 0.41%, 0.39% and 0.52%, respectively. There was no statistically significant difference between instrument systems. The percentage of teeth in which instruments fractured was 1.9% (0.28% for anterior teeth, 1.56% for pre-molars and 2.74% for molars). A total of 26 instruments fractured, of which 23 had tapers of 0.06 or greater. Most of the fragments were located in the apical third of the root canal, and both the median and mode amongst the fragment lengths were 2 mm. Conclusions: The low incidence of nickel-titanium rotary instrument fracture supports the continued use of these instruments in root canal treatment.
KW - Fracture
KW - Instrument
KW - Nickel-titanium
KW - Rotary
UR - http://www.scopus.com/inward/record.url?scp=33747122613&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33747122613&partnerID=8YFLogxK
U2 - 10.1111/j.1365-2591.2006.01137.x
DO - 10.1111/j.1365-2591.2006.01137.x
M3 - Article
C2 - 16916359
AN - SCOPUS:33747122613
SN - 0143-2885
VL - 39
SP - 700
EP - 708
JO - International Endodontic Journal
JF - International Endodontic Journal
IS - 9
ER -