Abstract
Muons decaying in the water volume of a Cherenkov detector of the Pierre Auger Observatory provide a useful calibration point at low energy. Using the digitized waveform continuously recorded by the electronics of each tank, we have devised a simple method to extract the charge spectrum of the Michel electrons, whose typical signal is about 1/8 of a crossing vertical muon. This procedure, moreover, allows continuous monitoring of the detector operation and of its water level. We have checked the procedure with high statistics on a test tank at the Observatory base and applied with success on the whole array.
Original language | English (US) |
---|---|
Pages | 299-302 |
Number of pages | 4 |
State | Published - 2005 |
Event | 29th International Cosmic Ray Conference, ICRC 2005 - Pune, India Duration: Aug 3 2005 → Aug 10 2005 |
Other
Other | 29th International Cosmic Ray Conference, ICRC 2005 |
---|---|
Country/Territory | India |
City | Pune |
Period | 8/3/05 → 8/10/05 |
ASJC Scopus subject areas
- Nuclear and High Energy Physics