TY - JOUR
T1 - Prostate cancer
T2 - Diffusion-weighted MR imaging for detection and assessment of aggressiveness-comparison between conventional and kurtosis models
AU - Tamada, Tsutomu
AU - Prabhu, Vinay
AU - Li, Jianhong
AU - Babb, James S.
AU - Taneja, Samir S.
AU - Rosenkrantz, Andrew B.
N1 - Publisher Copyright:
© 2017 RSNA.
PY - 2017/7
Y1 - 2017/7
N2 - Purpose: To compare standard diffusion-weighted (DW) imaging and diffusion kurtosis (DK) imaging for prostate cancer (PC) detection and characterization in a large patient cohort, with attention to the potential added value of DK imaging. Materials and Methods: This retrospective institutional review board-approved study received a waiver of informed consent. Two hundred eighty-five patients with PC underwent 3.0-T phased-array coil prostate magnetic resonance (MR) imaging, including a DK imaging sequence (b values 0, 500, 1000, 1500, and 2000 sec/mm2) before prostatectomy. Maps of apparent diffusion coefficient (ADC) and diffusional kurtosis (K) were derived by using maximal b values of 1000 and 2000 sec/mm2, respectively. Mean ADC and K were obtained from volumes of interest (VOIs) placed on each patient's dominant tumor and benign prostate tissue. Metrics were compared between benign and malignant tissue, between Gleason score (GS) ≤ 3 + 3 and GS ≥ 3 + 4 tumors, and between GS ≤ 3 + 4 and GS ≥ 4 + 3 tumors by using paired t tests, analysis of variance, receiver operating characteristic (ROC) analysis, and exact tests. Results: ADC and K showed significant differences for benign versus tumor tissues, GS ≤ 3 + 3 versus GS ≥ 3 + 4 tumors, and GS ≤ 3 + 4 versus GS ≥ 4 + 3 tumors (P < .001 for all). ADC and K were highly correlated (r = 20.82; P < .001). Area under the ROC curve was significantly higher (P = .002) for ADC (0.921) than for K (0.902) for benign versus malignant tissue but was similar for GS ≤ 3 + 3 versus GS ≥ 3 + 4 tumors (0.715-0.744) and GS ≤ 3 + 4 versus GS ≥ 4 + 3 tumors (0.694-0.720) (P > .15). ADC and K were concordant for these various outcomes in 80.0%-88.6% of patients; among patients with discordant results, ADC showed better performance than K for GS ≤ 3 + 4 versus GS ≥ 4 + 3 tumors (P = .016) and was similar to K for other outcomes (P > .136). Conclusion: ADC and K were highly correlated, had similar diagnostic performance, and were concordant for the various outcomes in the large majority of cases. These observations did not show a clear added value of DK imaging compared with standard DW imaging for clinical PC evaluation.
AB - Purpose: To compare standard diffusion-weighted (DW) imaging and diffusion kurtosis (DK) imaging for prostate cancer (PC) detection and characterization in a large patient cohort, with attention to the potential added value of DK imaging. Materials and Methods: This retrospective institutional review board-approved study received a waiver of informed consent. Two hundred eighty-five patients with PC underwent 3.0-T phased-array coil prostate magnetic resonance (MR) imaging, including a DK imaging sequence (b values 0, 500, 1000, 1500, and 2000 sec/mm2) before prostatectomy. Maps of apparent diffusion coefficient (ADC) and diffusional kurtosis (K) were derived by using maximal b values of 1000 and 2000 sec/mm2, respectively. Mean ADC and K were obtained from volumes of interest (VOIs) placed on each patient's dominant tumor and benign prostate tissue. Metrics were compared between benign and malignant tissue, between Gleason score (GS) ≤ 3 + 3 and GS ≥ 3 + 4 tumors, and between GS ≤ 3 + 4 and GS ≥ 4 + 3 tumors by using paired t tests, analysis of variance, receiver operating characteristic (ROC) analysis, and exact tests. Results: ADC and K showed significant differences for benign versus tumor tissues, GS ≤ 3 + 3 versus GS ≥ 3 + 4 tumors, and GS ≤ 3 + 4 versus GS ≥ 4 + 3 tumors (P < .001 for all). ADC and K were highly correlated (r = 20.82; P < .001). Area under the ROC curve was significantly higher (P = .002) for ADC (0.921) than for K (0.902) for benign versus malignant tissue but was similar for GS ≤ 3 + 3 versus GS ≥ 3 + 4 tumors (0.715-0.744) and GS ≤ 3 + 4 versus GS ≥ 4 + 3 tumors (0.694-0.720) (P > .15). ADC and K were concordant for these various outcomes in 80.0%-88.6% of patients; among patients with discordant results, ADC showed better performance than K for GS ≤ 3 + 4 versus GS ≥ 4 + 3 tumors (P = .016) and was similar to K for other outcomes (P > .136). Conclusion: ADC and K were highly correlated, had similar diagnostic performance, and were concordant for the various outcomes in the large majority of cases. These observations did not show a clear added value of DK imaging compared with standard DW imaging for clinical PC evaluation.
UR - http://www.scopus.com/inward/record.url?scp=85020948924&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85020948924&partnerID=8YFLogxK
U2 - 10.1148/radiol.2017162321
DO - 10.1148/radiol.2017162321
M3 - Article
C2 - 28394755
AN - SCOPUS:85020948924
SN - 0033-8419
VL - 284
SP - 100
EP - 108
JO - Radiology
JF - Radiology
IS - 1
ER -