TY - JOUR
T1 - Proton transfer reaction mass spectrometry and the unambiguous real-time detection of 2,4,6 trinitrotoluene
AU - Sulzer, Philipp
AU - Petersson, Fredrik
AU - Agarwal, Bishu
AU - Becker, Kurt H.
AU - Jürschik, Simone
AU - Märk, Tilmann D.
AU - Perry, David
AU - Watts, Peter
AU - Mayhew, Chris A.
PY - 2012/5/1
Y1 - 2012/5/1
N2 - Fears of terrorist attacks have led to the development of various technologies for the real-time detection of explosives, but all suffer from potential ambiguities in the assignment of threat agents. Using proton transfer reaction mass spectrometry (PTR-MS), an unusual bias dependence in the detection sensitivity of 2,4,6 trinitrotoluene (TNT) on the reduced electric field (E/N) has been observed. For protonated TNT, rather than decreasing signal intensity with increasing E/N, which is the more usual sensitivity pattern observed in PTR-MS studies, an anomalous behavior is first observed, whereby the signal intensity initially rises with increasing E/N. We relate this to unexpected ion-molecule chemistry based upon comparisons of measurements taken with related nitroaromatic compounds (1,3,5 trinitrobenzene, 1,3 dinitrobenzene, and 2,4 dinitrotoluene) and electronic structure calculations. This dependence provides an easily measurable signature that can be used to provide a rapid highly selective analytical procedure to minimize false positives for the detection of TNT. This has major implications for Homeland Security and, in addition, has the potential of making instrumentation cost-effective for use in security areas. This study shows that an understanding of fundamental ion-molecule chemistry occurring in low-pressure drift tubes is needed to exploit selectivity and sensitivity for analytical purposes.
AB - Fears of terrorist attacks have led to the development of various technologies for the real-time detection of explosives, but all suffer from potential ambiguities in the assignment of threat agents. Using proton transfer reaction mass spectrometry (PTR-MS), an unusual bias dependence in the detection sensitivity of 2,4,6 trinitrotoluene (TNT) on the reduced electric field (E/N) has been observed. For protonated TNT, rather than decreasing signal intensity with increasing E/N, which is the more usual sensitivity pattern observed in PTR-MS studies, an anomalous behavior is first observed, whereby the signal intensity initially rises with increasing E/N. We relate this to unexpected ion-molecule chemistry based upon comparisons of measurements taken with related nitroaromatic compounds (1,3,5 trinitrobenzene, 1,3 dinitrobenzene, and 2,4 dinitrotoluene) and electronic structure calculations. This dependence provides an easily measurable signature that can be used to provide a rapid highly selective analytical procedure to minimize false positives for the detection of TNT. This has major implications for Homeland Security and, in addition, has the potential of making instrumentation cost-effective for use in security areas. This study shows that an understanding of fundamental ion-molecule chemistry occurring in low-pressure drift tubes is needed to exploit selectivity and sensitivity for analytical purposes.
UR - http://www.scopus.com/inward/record.url?scp=84860461356&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84860461356&partnerID=8YFLogxK
U2 - 10.1021/ac3004456
DO - 10.1021/ac3004456
M3 - Article
C2 - 22482459
AN - SCOPUS:84860461356
SN - 0003-2700
VL - 84
SP - 4161
EP - 4166
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 9
ER -