Quantitative 3D-OCT motion correction with tilt and illumination correction, robust similarity measure and regularization

Martin F. Kraus, Jonathan J. Liu, Julia Schottenhamml, Chieh Li Chen, Attila Budai, Lauren Branchini, Tony Ko, Hiroshi Ishikawa, Gadi Wollstein, Joel Schuman, Jay S. Duker, James G. Fujimoto, Joachim Hornegger

Research output: Contribution to journalArticlepeer-review

Abstract

Variability in illumination, signal quality, tilt and the amount of motion pose challenges for post-processing based 3D-OCT motion correction algorithms. We present an advanced 3D-OCT motion correction algorithm using image registration and orthogonal raster scan patterns aimed at addressing these challenges. An intensity similarity measure using the pseudo Huber norm and a regularization scheme based on a pseudo L0.5 norm are introduced. A two-stage registration approach was developed. In the first stage, only axial motion and axial tilt are coarsely corrected. This result is then used as the starting point for a second stage full optimization. In preprocessing, a bias field estimation based approach to correct illumination differences in the input volumes is employed. Quantitative evaluation was performed using a large set of data acquired from 73 healthy and glaucomatous eyes using SD-OCT systems. OCT volumes of both the optic nerve head and the macula region acquired with three independent orthogonal volume pairs for each location were used to assess reproducibility. The advanced motion correction algorithm using the techniques presented in this paper was compared to a basic algorithm corresponding to an earlier version and to performing no motion correction. Errors in segmentation-based measures such as layer positions, retinal and nerve fiber thickness, as well as the blood vessel pattern were evaluated. The quantitative results consistently show that reproducibility is improved considerably by using the advanced algorithm, which also significantly outperforms the basic algorithm. The mean of the mean absolute retinal thickness difference over all data was 9.9 um without motion correction, 7.1 um using the basic algorithm and 5.0 um using the advanced algorithm. Similarly, the blood vessel likelihood map error is reduced to 69% of the uncorrected error for the basic and to 47% of the uncorrected error for the advanced algorithm. These results demonstrate that our advanced motion correction algorithm has the potential to improve the reliability of quantitative measurements derived from 3D-OCT data substantially.

Original languageEnglish (US)
Pages (from-to)2591-2613
Number of pages23
JournalBiomedical Optics Express
Volume5
Issue number8
DOIs
StatePublished - Aug 1 2014

ASJC Scopus subject areas

  • Biotechnology
  • Atomic and Molecular Physics, and Optics

Fingerprint

Dive into the research topics of 'Quantitative 3D-OCT motion correction with tilt and illumination correction, robust similarity measure and regularization'. Together they form a unique fingerprint.