TY - JOUR
T1 - Relation of Elevated Resting Heart Rate in Mid-Life to Cognitive Decline Over 20 Years (from the Atherosclerosis Risk in Communities [ARIC] Study)
AU - Wang, Stephanie
AU - Fashanu, Oluwaseun E.
AU - Zhao, Di
AU - Guallar, Eliseo
AU - Gottesman, Rebecca F.
AU - Schneider, Andrea L.C.
AU - McEvoy, John W.
AU - Norby, Faye L.
AU - Aladin, Amer I.
AU - Alonso, Alvaro
AU - Michos, Erin D.
N1 - Publisher Copyright:
© 2018
PY - 2019/1/15
Y1 - 2019/1/15
N2 - Resting heart rate (RHR) is independently associated with cardiovascular disease (CVD) risk. We determined whether RHR, measured in mid-life, is also associated with cognitive decline. We studied 13,720 middle-aged white and black ARIC participants without a history of stroke or atrial fibrillation. RHR was obtained from a 12-lead resting electrocardiogram at the baseline visit (1990 to 1992) and categorized into groups as <60 (reference), 60 to 69, 70 to 79 and ≥80 beats/min. Cognitive scores were obtained at baseline and at up to 2 additional visits (1996 to 1998 and 2011 to 2013). The primary outcome was a global composite cognitive score (Z-score) derived from 3 tests: delayed word recall, digit symbol substitution, and word fluency. The associations of RHR with cognitive decline and incident dementia were examined using linear mixed-effects and Cox hazard models, respectively, adjusting for sociodemographics, CVD risk factors, and AV-nodal blockade use. Multiple imputation methods were used to account for attrition over follow-up. Participants had mean ± SD age of 58 ± 6 years; 56% were women, 24% black. Average RHR was 66 ± 10 beats/min. Over a mean follow-up of 20 years, those with RHR ≥80 beats/min had greater global cognitive decline (average adjusted Z-score difference −0.12 [95% confidence interval −0.21, −0.03]) and increased risk for incident dementia (hazard ratio 1.28 (1.04, 1.57), compared with those with RHR <60 beats/min. In conclusion, elevated RHR is independently associated with greater cognitive decline and incident dementia over 20 years. Further studies are needed to determine whether the associations are causal or secondary to another underlying process, and whether modification of RHR can affect cognitive decline.
AB - Resting heart rate (RHR) is independently associated with cardiovascular disease (CVD) risk. We determined whether RHR, measured in mid-life, is also associated with cognitive decline. We studied 13,720 middle-aged white and black ARIC participants without a history of stroke or atrial fibrillation. RHR was obtained from a 12-lead resting electrocardiogram at the baseline visit (1990 to 1992) and categorized into groups as <60 (reference), 60 to 69, 70 to 79 and ≥80 beats/min. Cognitive scores were obtained at baseline and at up to 2 additional visits (1996 to 1998 and 2011 to 2013). The primary outcome was a global composite cognitive score (Z-score) derived from 3 tests: delayed word recall, digit symbol substitution, and word fluency. The associations of RHR with cognitive decline and incident dementia were examined using linear mixed-effects and Cox hazard models, respectively, adjusting for sociodemographics, CVD risk factors, and AV-nodal blockade use. Multiple imputation methods were used to account for attrition over follow-up. Participants had mean ± SD age of 58 ± 6 years; 56% were women, 24% black. Average RHR was 66 ± 10 beats/min. Over a mean follow-up of 20 years, those with RHR ≥80 beats/min had greater global cognitive decline (average adjusted Z-score difference −0.12 [95% confidence interval −0.21, −0.03]) and increased risk for incident dementia (hazard ratio 1.28 (1.04, 1.57), compared with those with RHR <60 beats/min. In conclusion, elevated RHR is independently associated with greater cognitive decline and incident dementia over 20 years. Further studies are needed to determine whether the associations are causal or secondary to another underlying process, and whether modification of RHR can affect cognitive decline.
UR - http://www.scopus.com/inward/record.url?scp=85056221742&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85056221742&partnerID=8YFLogxK
U2 - 10.1016/j.amjcard.2018.10.013
DO - 10.1016/j.amjcard.2018.10.013
M3 - Article
C2 - 30424869
AN - SCOPUS:85056221742
SN - 0002-9149
VL - 123
SP - 334
EP - 340
JO - American Journal of Cardiology
JF - American Journal of Cardiology
IS - 2
ER -