TY - JOUR
T1 - Reliability and failure modes of implant-supported Y-TZP and MCR three-unit bridges
AU - Bonfante, Estevam Augusto
AU - Coelho, Paulo Guilherme
AU - Navarro, Jose Manuel
AU - Pegoraro, Luiz Fernando
AU - Bonfante, Gerson
AU - Thompson, Van Purdy
AU - Silva, Nelson Renato Franç Alves
PY - 2010/9
Y1 - 2010/9
N2 - Purpose: Chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (yttria-tetragonal zirconia polycrystals [Y-TZP]) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus palladium-silver alloy (PdAg) three-unit bridges. Materials and Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n = 21 each), were fabricated, veneered, cemented (n = 3 each), and Hertzian contact-tested to obtain ultimate failure load. In each framework group, 18 specimens were distributed across three step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (two-sided at 90% confidence intervals) for a " mission" of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft, Tucson, AZ, USA). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusions: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300 N. Failure modes differed between materials.
AB - Purpose: Chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (yttria-tetragonal zirconia polycrystals [Y-TZP]) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus palladium-silver alloy (PdAg) three-unit bridges. Materials and Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n = 21 each), were fabricated, veneered, cemented (n = 3 each), and Hertzian contact-tested to obtain ultimate failure load. In each framework group, 18 specimens were distributed across three step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (two-sided at 90% confidence intervals) for a " mission" of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft, Tucson, AZ, USA). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusions: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300 N. Failure modes differed between materials.
KW - All-ceramic
KW - Fixed partial denture
KW - Mechanical testing
KW - Metal ceramic restoration
KW - Step-stress fatigue
KW - Y-TZP
UR - http://www.scopus.com/inward/record.url?scp=77955237947&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77955237947&partnerID=8YFLogxK
U2 - 10.1111/j.1708-8208.2009.00156.x
DO - 10.1111/j.1708-8208.2009.00156.x
M3 - Article
C2 - 19416277
AN - SCOPUS:77955237947
SN - 1523-0899
VL - 12
SP - 235
EP - 243
JO - Clinical Implant Dentistry and Related Research
JF - Clinical Implant Dentistry and Related Research
IS - 3
ER -