TY - JOUR
T1 - The effect of hip exoskeleton weight on kinematics, kinetics, and electromyography during human walking
AU - Normand, Michael A.
AU - Lee, Jeonghwan
AU - Su, Hao
AU - Sulzer, James S.
N1 - Publisher Copyright:
© 2023 Elsevier Ltd
PY - 2023/5
Y1 - 2023/5
N2 - In exoskeleton research, transparency is the degree to which a device hinders the movement of the user, a critical component of performance and usability. Transparency is most often evaluated individually, thus lacking generalization. Our goal was to systematically evaluate transparency due to inertial effects on gait of a hypothetical hip exoskeleton. We predicted that the weight distribution around the pelvis and the amount of weight applied would change gait characteristics. We instructed 21 healthy individuals to walk on a treadmill while bearing weights on the pelvis between 4 and 8 kg in three different configurations, bilaterally, unilaterally (left side) and on the lumbar portion of the back (L4). We measured kinematics, kinetics, and muscle activity during randomly ordered trials of 1.5 min at typical walking speed. We also calculated the margin of stability to measure medial–lateral stability. We observed that loading the hips bilaterally with 4 kg had no changes in kinematics, kinetics, dynamic stability, or muscle activity, but above 6 kg, sagittal joint power was increased. Loading the lumbar area increased posterior pelvic tilt at 6 kg and decreased dynamic stability at 4 kg, with many individuals reporting some discomfort. For the unilateral placement, above 4 kg dynamic stability was decreased and hip joint power was increased, and above 6 kg the pelvis begins to dip towards the loaded side. These results show the different effects of weight distribution around the pelvis. This study represents a novel, systematic approach to characterizing transparency in exoskeleton design (clinicaltrials.gov: NCT05120115).
AB - In exoskeleton research, transparency is the degree to which a device hinders the movement of the user, a critical component of performance and usability. Transparency is most often evaluated individually, thus lacking generalization. Our goal was to systematically evaluate transparency due to inertial effects on gait of a hypothetical hip exoskeleton. We predicted that the weight distribution around the pelvis and the amount of weight applied would change gait characteristics. We instructed 21 healthy individuals to walk on a treadmill while bearing weights on the pelvis between 4 and 8 kg in three different configurations, bilaterally, unilaterally (left side) and on the lumbar portion of the back (L4). We measured kinematics, kinetics, and muscle activity during randomly ordered trials of 1.5 min at typical walking speed. We also calculated the margin of stability to measure medial–lateral stability. We observed that loading the hips bilaterally with 4 kg had no changes in kinematics, kinetics, dynamic stability, or muscle activity, but above 6 kg, sagittal joint power was increased. Loading the lumbar area increased posterior pelvic tilt at 6 kg and decreased dynamic stability at 4 kg, with many individuals reporting some discomfort. For the unilateral placement, above 4 kg dynamic stability was decreased and hip joint power was increased, and above 6 kg the pelvis begins to dip towards the loaded side. These results show the different effects of weight distribution around the pelvis. This study represents a novel, systematic approach to characterizing transparency in exoskeleton design (clinicaltrials.gov: NCT05120115).
KW - Exoskeleton
KW - Gait
KW - Loading
KW - Weight
UR - http://www.scopus.com/inward/record.url?scp=85151470768&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85151470768&partnerID=8YFLogxK
U2 - 10.1016/j.jbiomech.2023.111552
DO - 10.1016/j.jbiomech.2023.111552
M3 - Article
C2 - 37004392
AN - SCOPUS:85151470768
SN - 0021-9290
VL - 152
JO - Journal of Biomechanics
JF - Journal of Biomechanics
M1 - 111552
ER -