Abstract
We describe a technique for mounting samples of filamentary A15 superconducting materials which give reliable results in Jc tests. We discuss the possible disadvantages of the method and how these are overcome.
Original language | English (US) |
---|---|
Pages (from-to) | 557-559 |
Number of pages | 3 |
Journal | Cryogenics |
Volume | 23 |
Issue number | 10 |
DOIs | |
State | Published - Oct 1983 |
Keywords
- critical current density
- filamentary A15
- superconductors
ASJC Scopus subject areas
- General Materials Science
- General Physics and Astronomy